1113-150-GE Whatman沃特曼定性滤纸Grade113 孔径30μm

产品型号1113-150

品       牌沃特曼

厂商性质代理商

产品简介

GE Whatman沃特曼定性滤纸Grade113 孔径30μm,非常高的负载能力,适合大颗粒过滤或者凝胶状沉淀的过滤。表面有褶皱,在定性滤纸中是Z厚的,常用于过滤树脂溶液。

详情介绍

名称 : GE Whatman沃特曼定性滤纸Grade113 孔径30μm

型号 : 1113-150

特点 : 由于加入了少量化学稳定树脂,这类滤纸非常坚韧,具有很高的湿强。普通应用中,不会因此引入显著的杂质。但树脂含氮,所以需要注意不能用于凯氏定氮。一些级别有预折叠型号提供。

详细描述

GE Whatman沃特曼定性滤纸Grade113 孔径30μm, 1113-150

Grade 113:30μm

非常高负载能力,适合大颗粒过滤或者凝胶状沉淀的过滤。表面有皱纹,在定性滤纸中是zui厚的。同时又有滤杯形式提供。预折叠型号Grade 113V

GE Whatman沃特曼定性滤纸Grade113 孔径30μm, 1113-150

1113-150-GE Whatman沃特曼定性滤纸Grade113 孔径30μm

GE Whatman沃特曼定性滤纸Grade113 孔径30μm, 1113-150

1113-150-GE Whatman沃特曼定性滤纸Grade113 孔径30μm

1113-110, 1113-090, 1113-125, 1113-150, 1113-185, 1113-240, 1113-320, 1113-500, 1113-917, 1113-991, 1600-113

GE Whatman沃特曼定性滤纸Grade113 孔径30μm, 1113-150

420400-GE whatman 47mm可换膜针头过滤器

  • 型号 420400
  • 品牌 GE whatman沃特曼
  • 【简单介绍】

    GE whatman 47mm可换膜针头过滤器 420400
    Pop-TopTM和Swin-LokTM塑料滤膜支撑器

    特性和优点

    l 使用正压,为小量液体的微滤和超纯而设计

    l 所有这三种滤膜支撑器均可与Nuclepore径迹蚀刻膜和组

    装膜相容使用

    l 与针头兼容

    GE whatman 47mm可换膜针头过滤器 420400

     

    Pop-TopTM和Swin-LokTM塑料滤膜支撑器

     

    特性和优点

    l 使用正压,为小量液体的微滤和超纯而设计

    l 所有这三种滤膜支撑器均可与Nuclepore径迹蚀刻膜和组

    装膜相容使用

    l 与针头兼容

    GE whatman 47mm可换膜针头过滤器 420400
    该换膜过滤器也可与WHATMAN系列无机膜配合使用
     
    Φ 25mm可换膜针头滤器(不锈钢) 1980-002 个
    Φ 13mm可换膜针头滤器(聚丙烯) 420100 个
    Φ 13mm可换膜针头滤器(聚丙烯) 420100 10个/包
    Φ 25mm可换膜针头滤器(聚丙烯) 420200 个
    Φ 25mm可换膜针头滤器(聚丙烯) 420200 10个/包
    Φ 47mm可换膜针头滤器(聚丙烯) 420400 个
    Φ 47mm可换膜针头滤器(聚丙烯) 420400 8个/包
    Φ 47mmx300ml不锈钢支架过滤器 1960-054 个
    Φ 47mmx250ml不锈钢支架过滤器 1960-052 个
    Φ 47mmx300ml玻璃支架过滤器 1960-004 个
    Φ 25mmx250ml玻璃支架过滤器 1960-002 
    Φ 4mm 0.2u 聚醚砜PSU 无菌针头滤器 6780-0402 50个/包
    Φ 4mm 0.45u 聚醚砜PSU 无菌针头滤器 6780-0404 50个/包
    Φ 4mm 0.2u 聚醚砜PSU 针头滤器 6782-0402 100个/包
    Φ 4mm 0.45u 聚醚砜PSU 针头滤器 6782-0404 100个/包
    Φ 4mm 0.2u PVDF无菌 针头滤器 6791-0402 个
    Φ 4mm 0.2u PVDF无菌 针头滤器 6791-0402 50个/盒
    0.2u 25mm 一次性聚醚砜无菌针头滤器 6794-2512 个
    0.2u 25mm 一次性聚醚砜无菌针头滤器 6794-2512 100个/盒
    0.45u 25mm 一次性聚醚砜无菌针头滤器 6794-2514 个
    0.45u 25mm 一次性聚醚砜无菌针头滤器 6794-2514 100个/盒
    0.2u 50mm 聚砜膜无菌滤器(过滤2-5L) 6724-5002 50个/包
    0.45u 50mm 聚砜膜无菌滤器(过滤2-5L) 6724-5045 
    13mm 0.45u 尼龙膜滤器 6790-1304 个
    13mm 0.45u 尼龙膜滤器 6790-1304 500个/盒
    13mm 0.2u 尼龙膜滤器 6790-1302 个
    13mm 0.2u 尼龙膜滤器 6790-1302 500个/盒
    13mm 0.45u PVDF单层滤器 6792-1304 个
    13mm 0.45u PVDF单层滤器 6792-1304 500个/盒
    Polycap 36 TF 空气过滤器 6700-3610 个
    盘状过滤器50mm 0.2u 6720-5002 50个/包
    滤膜镊子 1980-1004 个
    PH试纸 CF 0-14 6x80mm  2613-991 100条/盒
    PH试纸 CF 4.5-10 6x80mm 2614-991 100条/盒
    PH试纸CS条状1-12 2612-990 200条/盒
    PH试纸CS条状3.8-5.5 2627-990 200条/盒
    PH试纸CS条状6.0-8.1 2629-990 200条/盒
    膜过滤容器 (玻璃支架 /25ml 容器) 1960-002 套
    膜过滤容器 (玻璃支架 /100ml 容器) 1960-032 套
    膜过滤容器 (玻璃支架 /300ml 容器) 1960-004 套

    420400-GE whatman 47mm可换膜针头过滤器

10300212-GE WHATMAN 589/3孔径2um定量滤纸

  • 型号 10300212
  • 品牌 GE whatman沃特曼
  • 【简单介绍】

    GE WHATMAN 589/3孔径2um定量滤纸收集细小颗粒效率非常高,也用于很多工业日常分析
    方法,例如动植物脂肪和石油中不溶污染物质量的测定。已
    折叠好的型号为Grade 589/3 ½。

    GE WHATMAN 589/3孔径2um定量滤纸

    定量滤纸
    Grade 40 : 8 μm
    常规过滤用无灰滤纸,中等流速和颗粒保留度。用于水泥、
    泥土、金属成分比重分析。作为主要滤纸用于在土壤分析
    从水相提取物分离固形物质,在定量牛奶成分分析中,在
    原子吸收光谱之前作为纯分析级别洁净过滤。也用于大气
    中残留元素和放射性核素的高纯度收集,或作为浸渍滤纸
    收集大气中的酸性气体和碱性气体,食品及饲料中总砷含
    量、牧草中硝酸盐、蔬菜罐头中草酸、化肥中硼含量等。
    Grade 41 : 20 μm
    流速快的无灰滤纸,推荐用于诸如氢氧化铝或者氢氧化铁
    的分析过程中。也用于大颗粒或凝胶状沉淀物的过滤,比如
    铁矿中铁含量、镁矿中镁含量测定时过滤应用,还常作为环
    境空气污染物的测定,如悬浮颗粒物、气态化合物(如氟化
    物)等采样,或过滤消解溶液做光谱、色谱或质谱分析,如
    苦味suan浊度、食品中果胶酸等测定,41号滤纸还是标准泪液
    检测试纸的基体。该滤纸可用于一次性过滤漏斗中,这种方
    便的一次性47 mm过滤漏斗,大过滤量250 ml(产品编号
    1920-1441),47 mm Grade 41滤纸可以很容易取出用于进一
    步的分析或培养。
    Grade 42 : 2.5 μm
    在whatman所有纤维素滤纸中细的颗粒保留,是重量分
    析的世界标准。常用于诸如硫酸钡、偏锡酸、碳酸钙、碳
    酸锶等矿物质的元素含量测定、过滤汽油或有机溶剂,以
    及光谱和色谱样品的过滤制备,如原子吸收法(AAS)测定饲
    料中二月桂酸二丁基锡含量测定。
    Grade 43 : 16 μm
    颗粒保留介于Grade 40和41之间,但比Grade40快一倍。典
    型应用包括食品分析、土壤分析、空气污染监测中颗粒收
    集后进行荧光光谱法分析,也用于建筑业、矿产和钢铁业
    的无机分析。
    Whatman定量滤纸是为重量分析和仪器分析中样品制备而设
    计的。它们有三种形式来满足你的特别需求。
    无灰级:Grade 40~44 <0.007%,Grade 589< 0.01% – 非常
    纯的滤纸,是大部分主要分析过滤过程的理想用纸。
    硬化低灰:<0.015%, 经过强酸处理去除了微量金属,产
    生了高的湿强度和化学抗性,这些滤纸特别适合用于布氏
    漏斗,滤纸坚硬的光滑表面使得它很容易回收沉淀物。
    硬化无灰:<0.006%,非常低的灰分含量,酸硬化增加了
    湿强度和化学抗性。坚硬的表面使得这些滤纸适合于大多
    数主要过滤过程。
    定量滤纸―标准级
    Grade 44 : 3 μm
    Grade 42的薄型版本,截流更细小颗粒,但是每个样品的
    灰分更低,流速几乎是Grade 42的两倍。
    Grade 589/1 : 12-25 μm
    “黑缎滤纸”-定量分析粗沉淀物的标准滤纸(根据 DIN 53153定
    为2a类),是流速很高的无灰滤纸,用于很多定量标准方法,
    特别是重力应用(例如食物中灰分量的测定,水泥工业中Blaine
    细微颗粒测定)。已折叠好的型号为Grade 589 ½。
    Grade 589/2 : 4-12 μm
    “白缎滤纸”-中等细小颗粒的无灰标准滤纸(根据 DIN 53153定
    为2a类),中等流速,应用于多种日常定量分析方法,如泥
    土中沙子含量测定,面粉级别测定或者造纸工业中水相悬浮
    物测定,可可食品中脂肪含量、明胶中总磷、牛奶中沉淀物
    及产品异质物的测定。已折叠好的型号为Grade 589/2 ½。
    Grade 589/3 : 2μm
    “蓝缎滤纸”-是用于非常细小颗粒的无灰标准滤纸,流速慢,
    但是收集细小颗粒效率非常高,也用于很多工业日常分析
    方法,例如动植物脂肪和石油中不溶污染物质量的测定。已
    折叠好的型号为Grade 589/3 ½。

    GE WHATMAN 589/3孔径2um定量滤纸

    10300212-GE WHATMAN 589/3孔径2um定量滤纸10300212-GE WHATMAN 589/3孔径2um定量滤纸 

     

2800-250-GE Whatman沃特曼 提取套管25*100mm

产品型号2800-250

品       牌沃特曼

厂商性质代理商

产品简介

GE Whatman沃特曼 提取套管25*100mm ,25支/盒。由高纯纤维素棉绒制成。标准套管壁厚约为1mm(颗粒保留度为10μm)。

详情介绍

GE Whatman沃特曼 提取套管25*100mm

25支/盒。由高纯纤维素棉绒制成。标准套管壁厚约为1mm(颗粒保留度为10μm)。加厚型提取套管厚度约为2mm(颗粒保留度为6μm),用于高保留力和增加湿强度、干强度或特殊要求的应用。zui高操作温度达120℃。可供应内直径19-43mm,长度90-123mm的多种规格标准套管和加厚型套管。

GE Whatman沃特曼 提取套管25*100mm定货信息:

品名 规格 备注
2800-228纤维素提取套管 管类型 标准;内径×长度:22×80mm 25支/盒
2800-258纤维素提取套管 管类型标准 ;内径×长度:25×80mm 25支/盒
2800-250纤维素提取套管 管类型标准;内径×长度:25×100mm 25支/盒
2800-300纤维素提取套管 管类型标准 ;内径×长度:30×100mm 25支/盒
2800-338纤维素提取套管 管类型标准 ;内径×长度:33×80mm 25支/盒
2810-228纤维素提取套管 管类型加厚 ;内径×长度:22×80mm 25支/盒
2810-258纤维素提取套管 管类型加厚 ;内径×长度:25×80mm 25支/盒
2810-250纤维素提取套管 管类型加厚 ;内径×长度:25×100mm 25支/盒
2810-308纤维素提取套管 管类型加厚 ;内径×长度:30×80mm 25支/盒

1851-025-GE Whatman QMA石英滤纸

  • 型号 1851-025
  • 品牌 GE whatman沃特曼
  • 【简单介绍】

    GE Whatman QMA石英滤纸 1851-025
    简单介绍:
    硼硅酸玻璃,表面光滑,颗粒保留率高。可耐高温达500。特别推荐用于水污染监测、细胞收集、液闪计数和空气污染监测。

    GE Whatman QMA石英滤纸 1851-025

    简单介绍:
    硼硅酸玻璃,表面光滑,颗粒保留率高。可耐高温达500。特别推荐用于水污染监测、细胞收集、液闪计数和空气污染监测。
    Air Sampling Filters/Quartz Filters空气采样滤纸EPM2000
    由99%高纯硼硅复制成,可用于微量污染的详细化学分析。背景噪音低。
    为高流量空气采样机特别是PM-10空气采样机收集颗粒物和气溶胶样品而设计。
    石英滤纸-QM-A
    特纯石英纤维滤纸。特别推荐用于烟囱、烟道和烟雾方面空气污染监测工作。操作温度可达500摄氏度。滤纸经热处理,无粘合剂,重金属和碱土金属含量特别低。用于PM-10检测。
     
    WHATMAN石英滤膜QMA1851-025 产品详细介绍:
    空气采样滤纸-EPM2000
    EPM2000专门为高空气流量PM-10仪器而开发,可以收集大气中颗粒和气溶胶。它由99%高纯度硼硅酸玻璃制成,可用于微量污染的详细化学分析,背景干扰低。
    Whatman EPM 2000被EPA选用作为国家范围内高流量空气采样仪的标准滤器。每一张都被单独编号方便鉴别。
     
    石英滤纸-QM-A
    高纯度石英微纤维制成,用于酸性气体,烟囱,烟道方面的空气污染监测工作。特别适合于温度达500摄氏度和PM-10测试的环境。所含碱金属含量很低,“人造”硫酸盐和硝酸盐产物(来自二氧化硫盒二氧化氮)实际上减少了。QM-A根据EPA标准编号,在很多方面都可应用。

    GE Whatman QMA石英滤纸 1851-025

    1851-025-GE Whatman QMA石英滤纸

1444-070-GE WHATMAN 44号定量滤纸无灰滤纸

  • 型号 1444-070
  • 品牌 GE whatman沃特曼
  • 【简单介绍】

    GE WHATMAN 44号定量滤纸无灰滤纸Grade 44 : 3 μm
    Grade 42的薄型版本,截流更细小颗粒,但是每个样品的
    灰分更低,流速几乎是Grade 42的两倍。

    定量滤纸
    Grade 40 : 8 μm
    常规过滤用无灰滤纸,中等流速和颗粒保留度。用于水泥、
    泥土、金属成分比重分析。作为主要滤纸用于在土壤分析
    从水相提取物分离固形物质,在定量牛奶成分分析中,在
    原子吸收光谱之前作为纯分析级别洁净过滤。也用于大气
    中残留元素和放射性核素的高纯度收集,或作为浸渍滤纸
    收集大气中的酸性气体和碱性气体,食品及饲料中总砷含
    量、牧草中硝酸盐、蔬菜罐头中草酸、化肥中硼含量等。
    Grade 41 : 20 μm
    流速快的无灰滤纸,推荐用于诸如氢氧化铝或者氢氧化铁
    的分析过程中。也用于大颗粒或凝胶状沉淀物的过滤,比如
    铁矿中铁含量、镁矿中镁含量测定时过滤应用,还常作为环
    境空气污染物的测定,如悬浮颗粒物、气态化合物(如氟化
    物)等采样,或过滤消解溶液做光谱、色谱或质谱分析,如
    苦味suan浊度、食品中果胶酸等测定,41号滤纸还是标准泪液
    检测试纸的基体。该滤纸可用于一次性过滤漏斗中,这种方
    便的一次性47 mm过滤漏斗,大过滤量250 ml(产品编号
    1920-1441),47 mm Grade 41滤纸可以很容易取出用于进一
    步的分析或培养。
    Grade 42 : 2.5 μm
    在whatman所有纤维素滤纸中细的颗粒保留,是重量分
    析的世界标准。常用于诸如硫酸钡、偏锡酸、碳酸钙、碳
    酸锶等矿物质的元素含量测定、过滤汽油或有机溶剂,以
    及光谱和色谱样品的过滤制备,如原子吸收法(AAS)测定饲
    料中二月桂酸二丁基锡含量测定。
    Grade 43 : 16 μm
    颗粒保留介于Grade 40和41之间,但比Grade40快一倍。典
    型应用包括食品分析、土壤分析、空气污染监测中颗粒收
    集后进行荧光光谱法分析,也用于建筑业、矿产和钢铁业
    的无机分析。
    Whatman定量滤纸是为重量分析和仪器分析中样品制备而设
    计的。它们有三种形式来满足你的特别需求。
    无灰级:Grade 40~44 <0.007%,Grade 589< 0.01% – 非常
    纯的滤纸,是大部分主要分析过滤过程的理想用纸。
    硬化低灰:<0.015%, 经过强酸处理去除了微量金属,产
    生了高的湿强度和化学抗性,这些滤纸特别适合用于布氏
    漏斗,滤纸坚硬的光滑表面使得它很容易回收沉淀物。
    硬化无灰:<0.006%,非常低的灰分含量,酸硬化增加了
    湿强度和化学抗性。坚硬的表面使得这些滤纸适合于大多
    数主要过滤过程。
    Grade 44 : 3 μm
    Grade 42的薄型版本,截流更细小颗粒,但是每个样品的
    灰分更低,流速几乎是Grade 42的两倍。
    Grade 589/1 : 12-25 μm
    “黑缎滤纸”-定量分析粗沉淀物的标准滤纸(根据 DIN 53153定
    为2a类),是流速很高的无灰滤纸,用于很多定量标准方法,
    特别是重力应用(例如食物中灰分量的测定,水泥工业中Blaine
    细微颗粒测定)。已折叠好的型号为Grade 589 ½。
    Grade 589/2 : 4-12 μm
    “白缎滤纸”-中等细小颗粒的无灰标准滤纸(根据 DIN 53153定
    为2a类),中等流速,应用于多种日常定量分析方法,如泥
    土中沙子含量测定,面粉级别测定或者造纸工业中水相悬浮
    物测定,可可食品中脂肪含量、明胶中总磷、牛奶中沉淀物
    及产品异质物的测定。已折叠好的型号为Grade 589/2 ½。
    Grade 589/3 : 2μm
    “蓝缎滤纸”-是用于非常细小颗粒的无灰标准滤纸,流速慢,
    但是收集细小颗粒效率非常高,也用于很多工业日常分析
    方法,例如动植物脂肪和石油中不溶污染物质量的测定。已
    折叠好的型号为Grade 589/3 ½。

    GE WHATMAN 44号定量滤纸无灰滤纸

    1444-070-GE WHATMAN 44号定量滤纸无灰滤纸1444-070-GE WHATMAN 44号定量滤纸无灰滤纸

5802-240-GE Whatman沃特曼802 Fluted滤纸 预折叠纤维素滤纸

产品型号5802-240

品       牌沃特曼

厂商性质代理商

产品简介

Reeve Angel滤纸主要面向机械工程、照明工业、化工处理和电站行业要求,属于非惊喜化学分析的一种滤纸,因此这类滤纸一般不推荐用在只要、环境等分析,但是常用于啤酒样品的快速过滤。“GE Whatman沃特曼802 Fluted滤纸 预折叠纤维素滤纸”

详情介绍

GE Whatman沃特曼802 Fluted滤纸 预折叠纤维素滤纸

Reeve Angel滤纸主要面向机械工程、照明工业、化工处理和电站行业要求,属于非惊喜化学分析的一种滤纸,因此这类滤纸一般不推荐用在只要、环境等分析,但是常用于啤酒样品的快速过滤。

GE Whatman沃特曼802 Fluted滤纸 预折叠纤维素滤纸技术参数:

 

预折叠纤维素滤纸(v)
型号名称 产品描述 颗粒截留度(um) 负载能力 厚度/um 基本重量g/m2
800号 慢速,细颗粒物 1-5um 190 100
801号 湿强型,光滑表面 9-14um 中等 150 68
802号 湿强型,皱纹纸 5-30um 中等 260 73
830号 快速和高负载,皱纹纸 25-30um 400 123

订购信息:

5200-090 200号 9CM 100/PK

5200-125 200号 12.5CM 100/PK

5200-185 200号 18.5CM 100/PK

5211-185 211号 18.5CM 100/PK

5211-930 211号 58x58CM 100/PK

5226-190 226号 19CM 1000/PK

5226-200 226号 20CM 1000/PK

5226-330 226号 33cm 1000/PK

5226-848 226号 8INx8IN 1000/PK 

5230-090 230号 9CM 50/PK

5230-125 230号 12.5CM 50/PK

5230-185 230号 18.5CM 50/PK

5230-200 230号 20CM 50/PK

5230-240 230号 24CM 50/PK

5230-250 230号 25CM 50/PK

5230-330 230号 33CM 50/PK

5230-500 230号 50CM 50/PK

5201-090 201号 9CM 100/PK

5201-110 201号 11CM 100/PK

5201-150 201号 15CM 100/PK

5201-185 201号 18.5CM 100/PK

5201-240 201号 24CM 100/PK

5201-320 201号 32CM 100/PK

5201-330 201号 33CM 100/PK

5201-911 201号 14x19CM 500/PK

5201-940 201号 47x58CM 500/PK

5202-090 202号 9CM 100/PK 

5202-110 202号 11CM 100/PK 

5202-125 202号 12.5CM 100/PK

5202-150 202号 15CM 100/PK

5202-185 202号 18.5CM 100/PK

5202-200 202号 20CM 100/PK

5202-240 202号 24CM 100/PK

5202-250 202号 25CM 100/PK

5202-320 202号 32CM 100/PK

5202-330 202号 33CM 100/PK

5202-400 202号 40CM 100/PK

5305-110 305号 11CM 100/PK

5305-125 305号 12.5CM 100/PK

5305-150 305号 15CM 100/PK 

5307-110 307号 11CM 100/PK 

5307-125 307号 12.5CM 100/PK 

5307-150 307号 15CM 100/PK 

5309-110 309号 11CM 100/PK

5309-125 309号 12.5CM 100/PK

5309-150 309号 15CM 100/PK

5801-240 801号 24.0CM 100/PK

5801-320 801号 32.0CM 100/PK

5802-125 802号 12.5CM 100/PK

5802-150 802号 15CM 100/PK

5802-185 802号 18.5CM 100/PK

5802-240 802号 24CM 100/PK

5802-6698 802号 24CM 1000/PK

5802-320 802号 32CM 100/PK

5802-385 802号 38.5CM 100/PK

7402-004-GE/whatman水系尼龙膜直径47mm孔径0.2um

产品型号7402-004

品       牌沃特曼

厂商性质代理商

产品简介

GE/whatman水系尼龙膜直径47mm孔径0.2um高质量的尼龙膜适用于过滤水溶液和大多数有机溶液,广泛应用于生物学样品准备以及其他膜不适合或很难用的过滤。尼龙膜亲水性好,无润湿剂,因为凡是含润湿剂的微孔滤膜在过滤水溶液或有机溶剂时会被萃取出来而污染样品。尼龙膜柔韧性好、耐用、抗撕扯,能在135℃下高温灭菌。

详情介绍

GE/whatman水系尼龙膜直径47mm孔径0.2um

高质量的尼龙膜适用于过滤水溶液和大多数有机溶液,广泛应用于生物学样品准备以及其他膜不适合或很难用的过滤。尼龙膜亲水性好,无润湿剂,因为凡是含润湿剂的微孔滤膜在过滤水溶液或有机溶剂时会被萃取出来而污染样品。尼龙膜柔韧性好、耐用、抗撕扯,能在135℃下高温灭菌。

WHATMAN尼龙膜0.2um孔径Nylon Membrane Filters 7402-004技术参数:

整包数量: 100 片
亲水性:
纤维释放:
5psi下水流速: >50ml/min
材质: 尼龙
zui高操作温度: 135℃

WHATMAN尼龙膜0.8um孔径Nylon Membrane Filters 7408-004订购信息:

7402-001 NYL 13MM 0.2uM 100/PK
7402-002 NYL 25MM 0.2uM 100/PK
7402-004 NYL 47MM 0.2uM 100/PK
7402-009 NYL 90MM 0.2uM 50/PK
7404-001 NYL 13MM 0.45uM 100/PK
7404-002 NYL 25MM 0.45uM 100/PK
7404-004 NYL 47MM 0.45uM 100/PK
7404-009 NYL 90MM 0.45uM 50/PK
7408-004 NYL 47MM 0.8uM 100/PK
7410-004 NYL 47MM 1.0uM 100/PK

AE99 10548081-GE/whatmanNC膜 AE99孔径8um带被称

产品型号AE99 10548081

品       牌沃特曼

厂商性质代理商

产品简介

GE/whatmanNC膜 AE99孔径8um带被称尺寸25mm*50m一卷
AE99 25mm x 50m 1/pk
A general purpose membrane for use with most sample types that provides a good combination of sensitivity with fast wicking in a lateral

详情介绍

Solid. GHS product identifier Other means of identification Product type Section 1. Identification Chemical name Nitrocellulose Relevant identified uses of the substance or mixture and uses advised against Identified uses Not applicable. Uses advised against Reason GE Healthcare SAFETY DATA SHEET AE99 Membrane, Cellulose nitrate, 25 mm x 50 m Catalogue Number 10548081 9010548081 Singapore Supplier GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire HP7 9NA England GE Healthcare Pte Ltd. 1 Maritime Square #13-01 HarbourFront Center Singapore 099253 Emergency ephone number (with hours of operation) +65 6773 7303 (hours of operation: 8.30 pm – 5.30 pm) Confirms to Singapore standard SS 586 : part 3 : 2008 Use in laboratories Section 2. Hazards identification Classification of the substance or FLAMMABLE SOLIDS – Category 2 mixture Signal word Warning Hazard statements Flammable solid. Hazard pictograms Precautionary statements Prevention Wear protective gloves. Wear eye or face protection. Keep away from heat, sparks, open flames and hot surfaces. – No smoking. Response Not applicable. Storage Not applicable. Disposal Not applicable. Other hazards which do not result in classification None known. GHS label elements Validation date : 21 January 2016 Version 3 Article Number Page: 1/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Section 3. Composition/information on ingredients Nitrocellulose 100 9004-70-0 Ingredient name % CAS number There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. Chemical name Nitrocellulose Other means of identification CAS number 9004-70-0 Substance/mixture Product code 10548081 CAS number/other identifiers EC number Not available. Occupational exposure limits, if available, are listed in Section 8. Substance Chemical formula HNO3.xUnspecified No special recommendations. In case of contact with eyes, rinse immediay with plenty of water. Get medical attention if irritation occurs. Wash with soap and water. Get medical attention if irritation develops. No special recommendations. Section 4. First aid measures Eye contact Skin contact Inhalation Ingestion Protection of first-aiders No action shall be taken involving any personal risk or without suitable training. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Notes to physician In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours. Description of necessary first aid measures Specific treatments No specific treatment. Most important symptoms/effects, acute and delayed Inhalation Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure. Ingestion No known significant effects or critical hazards. Skin contact No known significant effects or critical hazards. Eye contact No known significant effects or critical hazards. Over-exposure signs/symptoms Skin contact Ingestion Inhalation No specific data. No specific data. No specific data. Eye contact No specific data. Potential acute health effects See toxicological information (Section 11) Indication of immediate medical attention and special treatment needed, if necessary Section 5. Fire-fighting measures Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool. Hazardous thermal decomposition products Specific hazards arising from the chemical Decomposition products may include the following materials: nitrogen oxides Flammable solid. Use dry chemical, CO?, water spray (fog) or foam. Extinguishing media Do not use water jet. Suitable extinguishing media Unsuitable extinguishing media Special protective actions for firefighters Validation date : 21 January 2016 Version 3 Article Number Page: 2/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Special protective equipment for fire-fighters Section 6. Accidental release measures Environmental precautions Personal precautions, protective equipment and emergency procedures Eliminate all ignition sources. Vacuum or sweep up material and place in a designated, labeled waste container. No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment. No special recommendations. Large spill Eliminate all ignition sources. Vacuum or sweep up material and place in a designated, labeled waste container. Small spill Methods and materials for containment and cleaning up For non-emergency personnel For emergency responders If specialised clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in “For non-emergency personnel”. Section 7. Handling and storage Conditions for safe storage, including any incompatibilities Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures. Store between the following temperatures: 18 to 25°C (64.4 to 77°F). Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination. Precautions for safe handling Protective measures Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequay ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use only non-sparking tools. Empty containers retain product residue and can be hazardous. Do not reuse container. Advice on general occupational hygiene None. Section 8. Exposure controls/personal protection Hand protection Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accuray estimated. Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields. Eye/face protection Environmental exposure controls No special recommendations. Appropriate engineering controls No special ventilation requirements. Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location. Hygiene measures Control parameters Individual protection measures Occupational exposure limits Skin protection Validation date : 21 January 2016 Version 3 Article Number Page: 3/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Respiratory protection A respirator is not needed under normal and intended conditions of product use. Body protection Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Other skin protection Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Section 9. Physical and chemical properties Physical state Melting point Vapor pressure Relative density Vapor density Solubility Solid. Not available. Not available. Not available. 0 kPa (0 mm Hg) [room temperature] Partially soluble in the following materials: methanol, diethyl ether and acetone. Insoluble in the following materials: cold water and hot water. Odor Odorless. pH Color White. Evaporation rate Not available. Auto-ignition temperature Flash point >160°C (>320°F) Closed cup: 12.85°C (55.1°F) Not available. Not applicable. Viscosity Dynamic (room temperature): Not applicable. Kinematic (room temperature): Not applicable. Odor threshold Not available. Partition coefficient: n-octanol/ water Appearance Boiling point Not available. Flammability (solid, gas) Product becomes a 'Flammable Solid category 2' after removing the membrane from the package. If the product is still in it's original packaging it is not a 'Flammable Solid category 2'. Lower and upper explosive (flammable) limits Not available. Burning rate Not available. Burning time Not available. SADT Not available. Decomposition temperature Not available. Solubility in water Not applicable. Section 10. Stability and reactivity Hazardous decomposition products Conditions to avoid Avoid all possible sources of ignition (spark or flame). Under normal conditions of storage and use, hazardous decomposition products should not be produced. Chemical stability The product is stable. Reactive or incompatible with the following materials: oxidizing materials Incompatible materials Possibility of hazardous reactions Under normal conditions of storage and use, hazardous reactions will not occur. Reactivity No specific test data related to reactivity available for this product or its ingredients. SADT Not available. Validation date : 21 January 2016 Version 3 Article Number Page: 4/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Section 11. Toxicological information Acute toxicity Nitrocellulose LD50 Oral Rat >5 g/kg – Product/ingredient name Result Species Dose Exposure Conclusion/Summary Not toxic. Not available. Conclusion/Summary Not toxic. Carcinogenicity Not available. Mutagenicity Not available. Teratogenicity Not available. Reproductive toxicity Not available. Irritation/Corrosion Not available. Sensitization Not available. Information on the likely routes of exposure Inhalation Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure. Ingestion No known significant effects or critical hazards. Skin contact No known significant effects or critical hazards. Eye contact No known significant effects or critical hazards. General No known significant effects or critical hazards. Carcinogenicity No known significant effects or critical hazards. Symptoms related to the physical, chemical and toxicological characteristics Skin contact Ingestion Inhalation No specific data. No specific data. No specific data. Eye contact No specific data. Potential chronic health effects Delayed and immediate effects and also chronic effects from short and long term exposure Specific target organ toxicity (single exposure) Specific target organ toxicity (repeated exposure) Not available. Not available. Aspiration hazard Not available. Information on toxicological effects Routes of entry not anticipated: Oral, Dermal, Inhalation. Potential acute health effects Potential immediate effects Not available. Short term exposure Potential delayed effects Not available. Potential immediate effects Not available. Long term exposure Potential delayed effects Not available. Validation date : 21 January 2016 Version 3 Article Number Page: 5/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Mutagenicity No known significant effects or critical hazards. Teratogenicity No known significant effects or critical hazards. Developmental effects No known significant effects or critical hazards. Fertility effects No known significant effects or critical hazards. Numerical measures of toxicity Not available. Acute toxicity estimates Section 12. Ecological information Bioaccumulative potential Other adverse effects No known significant effects or critical hazards. Not available. Toxicity Nitrocellulose Acute EC50 579000 µg/l Fresh water Algae – Pseudokirchneriella subcapitata 96 hours Product/ingredient name Result Species Exposure Conclusion/Summary No known significant effects or critical hazards. Persistence/degradability Soil/water partition coefficient (KOC) Not available. Mobility in soil Not available. Section 13. Disposal considerations The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible. This material and its container must be disposed of in a safe way. Care should be taken when handling emptied containers that have not been cleaned or rinsed out. Empty containers or liners may retain some product residues. Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Disposal methods Section 14. Transport information UN number – – – – – – – Not regulated. – – Not regulated. Not regulated. Remarks Product is not regulated as Dangerous Goods for transport according to a expert opinion by BAM (Bundesanstalt für Materialforschung and -prüfung) with number 2.2-91/15-E on 12 May 2015. “The above named nitrocellulose membrane filters (in form of round filters, pre-cut parts and curved parts) do not fulfill the criteria of Class 1 'Explosives' and the division 4.1 'Flammable Solids' Remarks The product is not regulated as Dangerous Goods for transport according to a expert opinion by BAM (Bundesanstalt für Materialforschung and -prüfung) with number 2. 2-91/15-E on 12 May 2015. “The above named nitrocellulose membrane filters (in form of round filters, pre-cut parts and curved parts) do not fulfill the criteria of Class 1 'Explosives' and the division 4.1 'Flammable Solids' Remarks The product is not regulated as Dangerous Goods for transport according to a expert opinion by BAM (Bundesanstalt für Materialforschung and -prüfung) with number 2.2-91/15-E on 12 May 2015. “The above named nitrocellulose membrane filters (in form of round filters, pre-cut parts and curved parts) do not fulfill the criteria of Class 1 'Explosives' and the division 4.1 'Flammable Solids' UN IMDG IATA UN proper shipping name Transport hazard class(es) Packing group Additional information Environmental hazards No. No. No. Validation date : 21 January 2016 Version 3 Article Number Page: 6/7 28417383 9528417383 AE99 Membrane, Cellulose nitrate, 25 mm x 50 m 10548081 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not available. of RID/ADR (GGVSE), IMDG-Code (GGVSee) and the ICAO-Technical Instructions.” of RID/ADR (GGVSE), IMDG-Code (GGVSee) and the ICAO-Technical Instructions.” of RID/ADR (GGVSE), IMDG-Code (GGVSee) and the ICAO-Technical Instructions.” Special precautions for user Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage. Section 15. Regulatory information Singapore – hazardous chemicals under government control None. Section 16. Other information History Date of printing Date of issue/Date of revision Version To the best of our knowledge, the information contained herein is accurate. However, neither the above-named supplier, nor any of its subsidiaries, assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist. Notice to reader Date of previous issue Indicates information that has changed from previously issued version. References Not available. Key to abbreviations ADN = European Provisions concerning the International Carriage of Dangerous Goods by Inland Waterway ADR = The European Agreement concerning the International Carriage of Dangerous Goods by Road ATE = Acute Toxicity Estimate BCF = Bioconcentration Factor GHS = Globally Harmonized System of Classification and Labelling of Chemicals IATA = International Air Transport Association IBC = Intermediate Bulk Container IMDG = International Maritime Dangerous Goods LogPow = logarithm of the octanol/water partition coefficient MARPOL 73/78 = International Convention for the Prevention of Pollution From Ships, 1973 as modified by the Protocol of 1978. (“Marpol” = marine pollution) RID = The Regulations concerning the International Carriage of Dangerous Goods by Rail UN = United Nations 27 November 2014. 3 26 January 2016 21 January 2016 Validation date : 21 January 2016 Version 3 Article Number Page: 7/7 28417383 9528417383

1823-010-GE whatmanGF/D 直径1cm玻璃纤维滤膜

  • 型号 1823-010
  • 品牌 GE whatman沃特曼
  • 【简单介绍】

    GE whatmanGF/D 直径1cm玻璃纤维滤膜GF/D: 2.7 μm
    GF/D玻纤膜的超高机械强度和优异

    GF/A: 1.6 μm
    无粘结剂,细小颗粒截留度好、流速快、负载力高,应用于
    药品测定之前药粉溶解液的精密过滤,或用于检测废水污染、
    空气污染、藻类和细菌培养、食品分析、蛋白过滤和ß-放射
    性免疫测定,以及放射性dian、汽车尾气烟气收集,还作为电
    池隔膜用于锂离子电池中,或电池材料的质量控制过程(如
    电极电位测定),GF/A提供一次性过滤漏斗。
    GF/B: 1.0 μm
    无粘结剂,厚度是GF/A的3倍,湿强度更高,小颗粒保留好,
    流速快,吸液率大,特别净化浑浊样品或有机溶剂的高温过
    滤,如毒素类样品前处理、二甲苯可溶物过滤等,也常做电
    池隔膜,及诊断试剂盒介质。
    GF/C: 1.2 μm
    无粘结剂,细小颗粒截留好,流速快,常作为检测饮用水和
    天然、工业废水的标准滤膜,还用于气相色谱样品前处理、
    细胞培养、液闪计数和免疫结合诊断试剂盒开发。
    GF/D: 2.7 μm
    无粘结剂,流速相当快,同等条件下滤速比棉纤维滤纸更快,
    负载力很高,常作为精密膜过滤之前的预过滤,或有机溶剂
    如油脂中污染物截留等,GF/D玻纤膜的超高机械强度和优异
    的吸液率性能,常作为锂离子电池隔膜以增加倍率性能。
    GF/F: 0.7 μm
    一种孔隙小的玻璃微纤维滤膜(0.6-0.8μm),无粘结剂,
    流速快,负载力很高。环境标准中固废浸出毒性实验就是以
    GF/F为分离介质,沿用至今。GF/F是“水质叶绿素测定”的标
    准玻纤滤膜。GF/F致密的毛细结构,可用于DNA吸附和纯化,
    或过滤细小的析出蛋白。GF/F通常与GF/D组成梯度过滤膜,
    处理大量的粘稠或难滤的生化溶液、流体及核酸样本。GF/F提供一次性过滤漏斗

    GE whatmanGF/D 直径1cm玻璃纤维滤膜

    1823-010-GE whatmanGF/D 直径1cm玻璃纤维滤膜1823-010-GE whatmanGF/D 直径1cm玻璃纤维滤膜